Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Nucleic Acids Res ; 51(W1): W542-W552, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37207333

RESUMO

SH2 domains are key mediators of phosphotyrosine-based signalling, and therapeutic targets for diverse, mostly oncological, disease indications. They have a highly conserved structure with a central beta sheet that divides the binding surface of the protein into two main pockets, responsible for phosphotyrosine binding (pY pocket) and substrate specificity (pY + 3 pocket). In recent years, structural databases have proven to be invaluable resources for the drug discovery community, as they contain highly relevant and up-to-date information on important protein classes. Here, we present SH2db, a comprehensive structural database and webserver for SH2 domain structures. To organize these protein structures efficiently, we introduce (i) a generic residue numbering scheme to enhance the comparability of different SH2 domains, (ii) a structure-based multiple sequence alignment of all 120 human wild-type SH2 domain sequences and their PDB and AlphaFold structures. The aligned sequences and structures can be searched, browsed and downloaded from the online interface of SH2db (http://sh2db.ttk.hu), with functions to conveniently prepare multiple structures into a Pymol session, and to export simple charts on the contents of the database. Our hope is that SH2db can assist researchers in their day-to-day work by becoming a one-stop shop for SH2 domain related research.


Assuntos
Sistemas de Informação , Proteínas , Domínios de Homologia de src , Humanos , Sequência de Aminoácidos , Sítios de Ligação , Fosfotirosina/metabolismo , Ligação Proteica , Proteínas/metabolismo , Internet , Bases de Dados de Proteínas
2.
J Cataract Refract Surg ; 42(2): 275-83, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27026453

RESUMO

PURPOSE: To describe the topographic and tomographic characteristics of normal fellow eyes of unilateral keratoconus cases and to evaluate the accuracy of machine learning classifiers in discriminating healthy corneas from the normal fellow corneas. SETTING: Department of Ophthalmology, Semmelweis University, Budapest, Hungary. DESIGN: Retrospective case-control study. METHODS: Patients with bilateral keratoconus (keratoconus group), clinically and according to the keratoconus indices of the Pentacam HR Scheimpflug camera; normal fellow eyes of patients with unilateral keratoconus (fellow-eye group); and eyes of refractive surgery candidates (control group) were compared. Tomographic data, topographic data, and keratoconus indices were measured in both eyes using the Scheimpflug camera. Receiver operating characteristic (ROC) analysis was used to assess the performance of automated classifiers trained on bilateral data as well as individual parameters to discriminate fellow eyes of patients with keratoconus from control eyes. RESULTS: Keratometry, elevation, and keratoconus indices values were significantly higher and pachymetry values were significantly lower in keratoconus eyes than in fellow eyes of unilateral keratoconus cases (P < .001). These fellow eyes had significantly higher keratometry, elevation, and keratoconus index values and significantly lower pachymetry values than control eyes (P < .001). Automated classifiers trained on bilateral data of index of height decentration had higher accuracy than the unilateral single parameter in discriminating fellow eyes of patients with keratoconus from control eyes (area under ROC 0.96 versus 0.88). CONCLUSION: Automatic classifiers trained on bilateral data were better than single parameters in discriminating fellow eyes of patients with unilateral keratoconus with preclinical signs of keratoconus from normal eyes. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Córnea/patologia , Técnicas de Diagnóstico Oftalmológico , Ceratocone/classificação , Ceratocone/diagnóstico , Aprendizado de Máquina/classificação , Fotografação/instrumentação , Adulto , Estudos de Casos e Controles , Paquimetria Corneana , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
Curr Eye Res ; 41(8): 1064-1067, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26681407

RESUMO

PURPOSE: To determine if pretreatment with topical nonsteroidal anti-inflammatory drug (NSAID) prior to femtosecond laser-assisted cataract surgery (FLACS) prevents intraoperative prostaglandin level elevation as a potential risk factor of postoperative complications. PATIENTS AND METHODS: Thirty-six patients with clinically significant cataract and without any concomitant general or ophthalmic disease were enrolled into the three age-matched groups of the study. The mean age of the patients was 62.3 ± 13.1 years. The first group of patients underwent traditional phacoemulsification (Control group), on the second group of patients FLACS was performed, and the third group of patients received topical 0.1% nepafenac pretreatment for 1one day prior to FLACS. Before the phacoemulsification part of the cataract surgery, approximately 110 µL of aqueous humor was collected in all groups. Total prostaglandin concentrations of the collected aqueous humor samples were evaluated by enzyme immunoassay (EIA). RESULTS: The mean of the total prostaglandin concentrations of the aqueous humor samples was 208.8 ± 140.5 pg/mL in patients in the control group, 1449.1 ± 1019.7 pg/mL in the FLACS group (p > 0.001), and 92.2 ± 51.7 pg/mL in the group pretreated with topical NSAID before the FLACS (p > 0.001 compared to FLACS; p > 0.01 compared to control), respectively. CONCLUSIONS: FLACS surgery increases intracameral prostaglandin concentration. However, using preoperative 1-day-long nonsteroid anti-inflammatory drops prior to FLACS, this intraoperative increase diminishes. Our study raises the possibility that NSAID pretreatment may be routinely administered before FLACS cataract surgeries to achieve a further decrease in the potential complications of increased total prostaglandin concentration during FLACS surgeries.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Humor Aquoso/metabolismo , Terapia a Laser/métodos , Facoemulsificação/métodos , Cuidados Pré-Operatórios/métodos , Prostaglandinas/metabolismo , Biomarcadores/metabolismo , Feminino , Seguimentos , Humanos , Técnicas Imunoenzimáticas , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Fatores de Tempo , Acuidade Visual
4.
Front Oncol ; 5: 94, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25954607

RESUMO

BACKGROUND: NOTCH signaling can exert oncogenic or tumor suppressive functions and can contribute to chemotherapy resistance in cancer. In this study, we aimed to clarify the clinicopathological significance and the prognostic and predictive value of NOTCH1 and NOTCH2 expression in gastric cancer (GC). METHODS: NOTCH1 and NOTCH2 expression was determined immunohistochemically in 142 primarily resected GCs using tissue microarrays and in 84 pretherapeutic biopsies from patients treated by neoadjuvant chemotherapy. The results were correlated with survival, response to therapy, and clinico-pathological features. RESULTS: Primarily resected patients with NOTCH1-negative tumors demonstrated worse survival. High NOTCH1 expression was associated with early-stage tumors and with significantly increased survival in this subgroup. Higher NOTCH2 expression was associated with early-stage and intestinal-type tumors and with better survival in the subgroup of intestinal-type tumors. In pretherapeutic biopsies, higher NOTCH1 and NOTCH2 expression was more frequent in non-responding patients, but these differences were statistically not significant. CONCLUSION: Our findings suggested that, in particular, NOTCH1 expression indicated good prognosis in GC. The close relationship of high NOTCH1 and NOTCH2 expression with early tumor stages may indicate a tumor-suppressive role of NOTCH signaling in GC. The role of NOTCH1 and NOTCH2 in neoadjuvantly treated GC is limited.

5.
J Refract Surg ; 31(3): 153-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25751830

RESUMO

PURPOSE: To evaluate and compare the mechanical properties of anterior capsule opening performed with femtosecond laser capsulotomy at different energy settings in ex vivo porcine anterior lens capsule specimens. METHODS: Twenty-five fresh porcine eyes per group were included in the study. Femtosecond laser capsulotomy was performed with three different pulse energy levels: 2 µJ (low energy group), 5 µJ (intermediate energy group), and 10 µJ (high energy group). The capsule openings were stretched with universal testing equipment until they ruptured. The morphologic profile of the cut capsule edges was evaluated using scanning electron microscopy. RESULTS: The high energy group had significantly lower rupture force (108 ± 14 mN) compared to the intermediate energy group (118 ± 10 mN) (P < .05) and low energy group (119 ± 11 mN) (P < .05), but the difference between the intermediate energy and low energy groups was not significant (P = .9479). The high energy group had significantly lower circumference stretching ratio (144% ± 3%) compared to the intermediate energy group (148% ± 3%) (P < .05) and low energy group (148% ± 3%) (P < .05), but the difference between the intermediate energy group and low energy group was not significant (P = .9985). Scanning electron microscopy images showed that the edge was only serrated with low and intermediate energy, but additional signs of collagen melting and denaturation were observed at high energy. CONCLUSIONS: Anterior capsule openings created at a high energy level were slightly weaker and less extensible than those created at low or intermediate levels, possibly due to the increased thermal effect of photo-disruption.


Assuntos
Cápsula Anterior do Cristalino/fisiologia , Elasticidade/fisiologia , Capsulotomia Posterior/métodos , Animais , Cápsula Anterior do Cristalino/cirurgia , Cápsula Anterior do Cristalino/ultraestrutura , Fenômenos Biomecânicos , Microscopia Eletrônica de Varredura , Suínos
6.
Orv Hetil ; 156(6): 221-5, 2015 Feb 08.
Artigo em Húngaro | MEDLINE | ID: mdl-25639636

RESUMO

INTRODUCTION: Femtosecond laser-assisted cataract surgery improved the results of cataract surgeries. AIM: Outcome analysis of femtosecond laser-assisted cataract surgery using the novel 2.16 software and the SoftFit(®) Patient Interface. METHOD: The novel software and the newly developed Patient Interface were used in 100 eyes of 100 patients. RESULTS: Length of femtosecond laser pretreatment decreased to 45-60 seconds. The smaller size of the new patient interface resulted in easier docking even on pediatric eyes. Suction force used for docking decreased from 40-50 mmHg to 16-20 mmHg. Incidence rate of subconjunctival suffusion decreased from 40% to 15-20% and its clinical severity was reduced, too. No corneal microfolds evolved, thus the incidence rate of the free-floating capsulotomies increased from 30% to 97%. The total energy of femtosecond laser pretreatment was decreased by almost 50%. Corneal wounds had the desired structure, and they were easy to open and closed precisely. CONCLUSIONS: The SoftFit(®) patient interface and the novel software widened the possible uses of the femtosecond laser-assisted cataract surgery, e.g. in pediatric ophthalmology. Innovations improved the safety and the predictability of the method.


Assuntos
Extração de Catarata/instrumentação , Extração de Catarata/métodos , Terapia a Laser/métodos , Implante de Lente Intraocular , Capsulotomia Posterior/estatística & dados numéricos , Software , Adolescente , Adulto , Idoso , Extração de Catarata/efeitos adversos , Criança , Feminino , Humanos , Terapia a Laser/instrumentação , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual
7.
J Refract Surg ; 30(8): 522-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25325892

RESUMO

PURPOSE: To evaluate femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism (SIA) and corneal higher-order aberrations (HOAs). METHODS: In a prospective randomized study, conventional phacoemulsification with a 2.8-mm clear corneal incision using a disposable keratome was performed in 20 eyes of 20 patients (manual group), and femtosecond laser-assisted cataract surgery with a 2.8-mm biplanar clear corneal tunnel created by a femtosecond laser (LenSx; Alcon Laboratories, Inc., Aliso Viejo, CA) was performed in 20 eyes of 20 patients (femtosecond laser group). Corneal topography readings and corneal wavefront aberrations (diameter: 9.0 mm) were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgerate, Wetzlar, Germany) preoperatively and 3 months postoperatively. RESULTS: There was no significant difference in SIA between the groups (femtosecond laser group: 0.47 ± 0.13 vs manual group: 0.41 ± 0.14; P = .218), but the axis deviation of the SIA axis from the previously planned axis was significantly smaller in the femtosecond laser group compared to the manual group (4.47°± 2.59° vs 7.38°± 4.72°, respectively; P = .048). Corneal HOAs increased significantly in both groups (femtosecond laser group: 0.13 ± 0.09 to 0.18 ± 0.12, P = .025; manual group: 0.13 ± 0.05 to 0.15 ± 0.05, P = .002), but preoperative and postoperative values did not differ significantly between them (P = .472 and .078, respectively). Lower-order and total corneal aberration values remained stable in both groups (P > .05). CONCLUSIONS: There was no difference in SIA and induced HOAs between manual and femtosecond laser-created clear corneal incisions.


Assuntos
Astigmatismo/etiologia , Córnea/cirurgia , Cirurgia da Córnea a Laser/efeitos adversos , Aberrações de Frente de Onda da Córnea/etiologia , Implante de Lente Intraocular/métodos , Procedimentos Cirúrgicos Oftalmológicos/efeitos adversos , Facoemulsificação/métodos , Idoso , Astigmatismo/diagnóstico , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
J Refract Surg ; 30(10): 660-4, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25291748

RESUMO

PURPOSE: To evaluate and compare the mechanical properties of anterior capsule openings performed with the continuous curvilinear capsulorhexis (CCC) technique and femtosecond laser capsulotomy (FLC) in ex vivo porcine lens capsule specimens. METHODS: Fresh porcine eyes were included in the study (CCC group, n = 50; FLC group, n = 30). The capsule openings were stretched with universal testing equipment until they ruptured. The rupture force and circumference stretching ratio were evaluated. The morphologic profile of the cut capsule edges was evaluated using scanning electron microscopy (SEM). RESULTS: The average rupture force was higher in the CCC group (median: 155 mN; interquartile range [IQR]: 129 to 201 mN; range: 71 to 294 mN) than in the FLC group (median: 119 mN; IQR: 108 to 128 mN; range: 91 to 142 mN) (P < .01, Mann-Whitney U test). The average circumference stretching ratio in the CCC group was greater (median: 150%; IQR: 146% to 156%; range: 136% to 161%) than in the FLC group (median: 148%; IQR: 145% to 150%; range: 141% to 154%) (P = .0468, Mann-Whitney U test). When less than 71 mN, no capsular tear occurred in either group. When less than 91 mN, no capsular tear occurred in the FLC group, whereas at 91 mN, the probability of capsular tears was 9% for the CCC group. SEM examination found that the CCC group had smooth edges, whereas those of the FLC group were gently serrated. CONCLUSIONS: According to the current results in a porcine eye model, FLC had less average resistance to capsule tear than CCC, but the weakest openings were seen in the CCC group.


Assuntos
Cápsula Anterior do Cristalino/fisiologia , Fenômenos Biomecânicos/fisiologia , Capsulorrexe , Terapia a Laser , Animais , Cápsula Anterior do Cristalino/cirurgia , Cápsula Anterior do Cristalino/ultraestrutura , Microscopia Eletrônica de Varredura , Ruptura da Cápsula Posterior do Olho/fisiopatologia , Estresse Mecânico , Suínos
9.
Eur J Ophthalmol ; 24(4): 623-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24519509

RESUMO

PURPOSE: To report the use of femtosecond laser cataract surgery in a traumatic case. METHODS: A 38-year-old man had a penetrating eye injury while working with wire. The corneal laceration was sutured first. In the postoperative period, cortical cataract appeared in the crystalline lens; therefore, in the second session, cataract surgery was performed using a femtosecond laser system (Alcon-LenSx Lasers Inc.). RESULTS: Corneal incisions, an intact 4.5 mm capsulorhexis, and nucleus liquefaction were performed with the femtosecond laser. Corrected distance visual acuity was 0.9 1 month after surgery. CONCLUSIONS: Femtosecond laser is an effective method in traumatic cataract cases after penetrating eye injury. Corneal incisions, capsulorhexis, and nucleus liquefaction can be performed precisely and safety.


Assuntos
Cápsula Anterior do Cristalino/lesões , Lesões da Córnea , Ferimentos Oculares Penetrantes/etiologia , Terapia a Laser/métodos , Facoemulsificação/métodos , Adulto , Cápsula Anterior do Cristalino/cirurgia , Córnea/cirurgia , Ferimentos Oculares Penetrantes/cirurgia , Humanos , Implante de Lente Intraocular , Masculino , Tomografia de Coerência Óptica , Acuidade Visual
10.
J Cataract Refract Surg ; 40(1): 20-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24355719

RESUMO

PURPOSE: To analyze complications of femtosecond lasers used for cataract surgery. SETTING: Department of Ophthalmology Semmelweis University, Budapest, Hungary. DESIGN: Retrospective analysis. METHODS: Intraoperative complications of the first 100 femtosecond laser-assisted (Alcon-Lensx, Inc.) cataract surgeries were collected. Possible complications of femtosecond capsulotomies and their management were also assessed. RESULTS: The complications were as follows: suction break (2%), conjunctival redness or hemorrhage (34%), capsule tags and bridges (20%), anterior tear (4%), miosis (32%), and endothelial damage due to cut within the endothelial layer (3%). There were no cases of capsule blockage or posterior capsule tear. During the learning curve, there was no complication that would require vitrectomy. All complications occurred during the first 100 cases. CONCLUSIONS: Femtosecond laser cataract surgery had a learning curve during the first 100 cases. With cautious surgical technique, the complications can be avoided. The femtosecond laser-assisted method was efficient and safe for cataract surgery.


Assuntos
Extração de Catarata/métodos , Complicações Intraoperatórias , Terapia a Laser/métodos , Extração de Catarata/educação , Humanos , Curva de Aprendizado , Implante de Lente Intraocular , Refração Ocular/fisiologia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
11.
J Refract Surg ; 29(9): 645-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23777238

RESUMO

PURPOSE: To report the use of femtosecond laser-assisted cataract surgery in management of phacomorphic glaucoma. METHODS: An 89-year-old patient developed acute phacomorphic glaucoma in her right eye with elevated intraocular pressure (62 mm Hg), shallow anterior chamber, and mature cataract. After conservative antiglaucoma therapy and Nd:YAG iridotomy, femtosecond laser-assisted cataract surgery was performed. A Malyugin ring was implanted for mechanical pupil dilatation and a 4.8-mm capsulorrhexis and lens fragmentation was performed using a femtosecond laser system (Alcon LenSx Inc., Aliso Viejo, CA) followed by in-the-bag intraocular lens implantation. RESULTS: Intact 4.8-mm capsulorrhexis and successful lens fragmentation could be performed using femtosecond laser. After cataract surgery, the patient's visual acuity increased from hand motions to 0.4 (Snellen 4/10) and the intraocular pressure returned to normal range without antiglaucoma drop therapy. CONCLUSIONS: The results indicate that femtosecond laser can be successfully used in certain cases of phacomorphic glaucoma, even if mechanical pupil dilatation is needed.


Assuntos
Capsulorrexe/métodos , Catarata/complicações , Córnea/cirurgia , Glaucoma de Ângulo Fechado/cirurgia , Terapia a Laser/métodos , Refração Ocular , Idoso de 80 Anos ou mais , Catarata/fisiopatologia , Feminino , Glaucoma de Ângulo Fechado/complicações , Glaucoma de Ângulo Fechado/fisiopatologia , Humanos , Acuidade Visual
13.
J Refract Surg ; 29(2): 110-2, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23380411

RESUMO

PURPOSE: To report the anterior segment imaging characteristics after femtosecond laser assisted cataract surgery. METHODS: Cataract surgery was performed with the LenSx femtosecond laser (Alcon-LenSx Inc., Aliso Viejo, CA) in 40 eyes of 40 patients. The laser was programmed to perform a 4.5-mm capsulorhexis, a cross-pattern fragmentation of the nucleus, a 2.8-mm main incision, and a 1.0-mm side-port incision. The anterior segment was then analyzed using the Visante OCT anterior segment program (Zeiss-Meditec AG, Jena, Germany). RESULTS: The preoperatively set treatment parameters correlated well with the achieved results. For the capsulorhexis, the femtosecond laser cut was programmed to start 350 µm behind the anterior lens capsule and OCT measured 377 ± 55.3 µm. Nucleus fragmentation was programmed to start 750 µm in front of the posterior capsule and end 550 µm behind the anterior capsule, and OCT measured 794 ± 111 and 568 ± 147 µm, respectively. The diameter of the capsulorhexis measured by OCT was 4.54 ± 0.2 mm, compared to the 4.5 mm programmed. CONCLUSIONS: Anterior segment OCT imaging was able to detect the tissue changes within the lens after femtosecond laser capsulorhexis and nucleus fragmentation. The measured values correlated well with the planned treatment parameters.


Assuntos
Segmento Anterior do Olho/patologia , Extração de Catarata , Terapia a Laser , Tomografia de Coerência Óptica , Capsulorrexe/métodos , Humanos , Período Pós-Operatório , Cicatrização
15.
J Refract Surg ; 28(9): 609-13, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22947287

RESUMO

PURPOSE: To evaluate the long-term visual outcome and intraocular (IOL) position parameters with a single-optic accommodating IOL after 5.5- or 6.0-mm femtosecond laser capsulotomy. METHODS: This prospective, randomized, pilot study comprised 17 eyes from 11 patients (7 men) with a mean age of 65.82±10.64 years (range: 51 to 79 years). All patients received a Crystalens AT-50AO (Bausch & Lomb) accommodating IOL after femtosecond laser refractive cataract surgery using either a 5.5-mm capsulotomy (5.5-mm group; 9 eyes) or 6.0-mm capsulotomy (6.0-mm group; 8 eyes). Near and distance visual acuities, manifest refraction spherical equivalent (MRSE), and IOL tilt and decentration were evaluated 1 year postoperatively. RESULTS: No significant differences were noted between groups for postoperative uncorrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, and MRSE. Vertical and horizontal tilt were significantly higher in the 6.0-mm group than in the 5.5-mm group (P=.014 and P=.015, respectively). No significant difference was observed between groups regarding IOL decentration. CONCLUSIONS: A 5.5-mm capsulotomy created with a femtosecond laser is associated with less IOL tilt and therefore may be superior to a 6.0-mm capsulotomy when implanting a single-optic accommodating IOL.


Assuntos
Capsulorrexe/métodos , Terapia a Laser/métodos , Implante de Lente Intraocular , Lentes Intraoculares , Acuidade Visual/fisiologia , Acomodação Ocular/fisiologia , Idoso , Migração do Implante de Lente Intraocular/prevenção & controle , Feminino , Humanos , Lasers de Excimer , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Refração Ocular/fisiologia , Resultado do Tratamento
16.
J Refract Surg ; 28(8): 540-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22785062

RESUMO

PURPOSE: To compare intraocular lens (IOL) power calculation and refractive outcome between patients who underwent laser refractive cataract surgery with a femtosecond laser and those with conventional cataract surgery. METHODS: In this prospective study, 77 eyes from 77 patients underwent laser refractive cataract surgery (laser group; Alcon LenSx femtosecond laser), and conventional cataract surgery with phacoemulsification was performed in 57 eyes from 57 patients (conventional group). Biometry was done with optical low coherence reflectometry (Lenstar LS900, Haag-Streit AG), and IOL calculation was performed with third-generation IOL formulas (SRK/T, Hoffer Q, and Holladay). The refractive outcome was analyzed using the mean absolute error (MAE; difference between predicted and achieved postoperative spherical equivalent refraction), and multivariable regression analysis was performed to compare the two groups. RESULTS: No significant differences were found between age, axial length, keratometry, and preoperative corrected visual acuity in the laser and conventional groups (P>.05; Mann-Whitney U test). At least 6 weeks after surgery, MAE was significantly lower in the laser group (0.38±0.28 diopters [D]) than in the conventional group (0.50±0.38 D) (P=.04). The difference was the greatest in short (axial length <22.0 mm, 0.43±0.41 vs 0.63±0.48) and long (axial length >26.0 mm, 0.33±0.24 vs 0.63±0.42) eyes. CONCLUSIONS: Laser refractive cataract surgery with a femtosecond laser resulted in a significantly better predictability of IOL power calculation than conventional phacoemulsification surgery. This difference is possibly due to a more precise capsulorrhexis, resulting in a more stable IOL position.


Assuntos
Extração de Catarata/métodos , Terapia a Laser/métodos , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação/métodos , Refração Ocular/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biometria , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
17.
J Refract Surg ; 28(6): 387-91, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22589291

RESUMO

PURPOSE: To compare the effect of conventional phacoemulsification and femtosecond laser-assisted cataract surgery on the cornea using Scheimpflug imaging and noncontact specular microscopy. METHODS: In each group, 38 eyes (38 patients) underwent cataract surgery using either femtosecond laser-assisted (Alcon LenSx laser) (femtolaser group) or conventional phacoemulsification (phaco group). Central corneal thickness, 3-mm corneal volume, and Pentacam Nucleus Staging (PNS) were determined by a rotating Scheimpflug camera (Pentacam HR, Oculus Optikgeräte GmbH), and the volume stress index was calculated at 1 day and 1 month postoperatively. Endothelial cell count was measured by noncontact specular microscopy preoperatively, 1 day, 1 week, and 1 month postoperatively. RESULTS: Central corneal thickness was significantly higher in the phaco group (607±91 µm) than in the femtolaser group (580±42 µm) on day 1, but did not differ significantly preoperatively and at 1 week and 1 month. Volume stress index at day 1 was significantly lower in the femtolaser group than in the phaco group (P<.05) but did not differ significantly at 1 month. Multivariate regression analysis showed that the type of surgery had a significant effect on central corneal thickness. CONCLUSIONS: Femtosecond laser-assisted cataract surgery causes less corneal swelling in the early postoperative period and may cause less trauma to corneal endothelial cells than manual phacoemulsification.


Assuntos
Extração de Catarata , Córnea/patologia , Endotélio Corneano/patologia , Terapia a Laser/métodos , Facoemulsificação/métodos , Idoso , Contagem de Células , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Tamanho do Órgão , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
18.
J Cataract Refract Surg ; 38(6): 941-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22624892

RESUMO

PURPOSE: To evaluate and compare thickness changes in the retinal layers in the macula with optical coherence tomography (OCT) segmentation software after femtosecond laser-assisted phacoemulsification (study group) and conventional phacoemulsification (control group). SETTING: Department of Ophthalmology, Semmelweis University, Budapest, Hungary. DESIGN: Case-control study. METHODS: Total retinal thickness of the macula was evaluated using Stratus OCT 4 to 8 weeks postoperatively. The OCT images were segmented using OCT retinal image analysis software. Regional thickness data in the central area, inner rings, and outer rings were obtained and absolute and relative thicknesses of the individual retinal layers in the 2 study groups compared. Relative thickness was calculated as the ratio of the retinal layer to the total retinal thickness. RESULTS: All surgeries were uneventful. Statistically significant differences were found in absolute outer nuclear layer thickness and relative outer nuclear layer thickness in the inner and outer macular rings between the 2 groups. After adjusting for effective phaco time in multivariate modeling, type of surgery showed a significantly lower relative outer nuclear layer ratio in the inner retinal ring (0.26 with 95% confidence interval [CI], 0.25-0.27 versus 0.28 with 95% CI, 0.27-0.29; P=.03) and in the outer retinal ring (0.27 with 95% CI, 0.25-0.28 versus 0.29 with 95% CI, 0.28-0.31; P=.02) in the study group. CONCLUSION: After cataract surgery, macular edema was detectable mainly in the outer nuclear layer in both groups but was significantly less using the femtosecond laser platform.


Assuntos
Terapia a Laser , Lasers de Excimer , Edema Macular/diagnóstico , Facoemulsificação/métodos , Complicações Pós-Operatórias/diagnóstico , Retina/patologia , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
J Refract Surg ; 28(4): 259-63, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22496437

RESUMO

PURPOSE: To compare intraocular lens (IOL) decentration and tilt following a circular capsulotomy created with a femtosecond laser (laser CCC) to a manually performed continuous curvilinear capsulorrhexis (manual CCC). METHODS: In a prospective, randomized study, a laser CCC (Alcon LenSx Inc) was performed in 20 eyes from 20 patients and a manual CCC was performed in 25 eyes from 25 patients. Intraocular lens decentration and tilt were measured using a Scheimpflug camera (Pentacam, Oculus Optikgeräte GmbH) 1 year after surgery. Uncorrected (UDVA) and corrected distance visual acuity (CDVA) and manifest refraction were also determined postoperatively. Between-group differences of IOL decentration and tilt as well as the correlation between IOL decentration and postoperative refractive changes and between IOL tilt and visual acuity were analyzed. RESULTS: Horizontal and vertical tilt were significantly higher in the manual CCC group (P=.007 and P<.001, respectively). Lenses implanted after manual CCC showed greater horizontal and total decentration (P=.034 and P=.022, respectively). Significant differences were found in the homogeneity of dichotomized IOL vertical tilt and both horizontal and total decentration distribution (P=.008, P=.036, and P=.017, respectively). Total IOL decentration showed a significant correlation with changes in manifest refraction values between 1 month and 1 year after surgery (R=0.33, P=.032). A significant correlation was noted between IOL vertical tilt and CDVA (R(2)=0.17, ß=-0.41, 95% confidence limit: -0.69 to -0.13, P=.005). CONCLUSIONS: Continuous curvilinear capsulorrhexis created with a femtosecond laser resulted in a more stable refractive result and less IOL tilt and decentration than manual CCC.


Assuntos
Cápsula Anterior do Cristalino/cirurgia , Migração do Implante de Lente Intraocular/diagnóstico , Capsulorrexe/métodos , Terapia a Laser , Fotografação/métodos , Idoso , Migração do Implante de Lente Intraocular/etiologia , Migração do Implante de Lente Intraocular/prevenção & controle , Feminino , Humanos , Lasers de Excimer , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
20.
J Refract Surg ; 28(2): 151-3, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22313435

RESUMO

PURPOSE: To investigate the use of femtosecond laser cataract surgery in traumatic cataracts of different origin. METHODS: The first case developed acute traumatic cataract due to penetrating injury of the cornea and the anterior lens capsule; the second developed traumatic cataract 11 years after a penetrating corneal injury; and the third developed a "white" cataract 12 months after blunt ocular trauma. In all cases, 4.5-mm capsulorrhexis and corneal incisions were performed using a femtosecond laser system (Alcon LenSx Inc), and nucleus liquefaction with the laser was performed additionally in the second case. RESULTS: In all patients, a capsulorrhexis could be created with the femtosecond laser. Preexisting radial tears were present in the first case, but the remaining anterior capsule could be cut with the laser. The second and third cases showed an intact 4.5-mm capsulorrhexis. Corneal incisions were stable in all cases, and nucleus liquefaction was possible in the second case (grade 1-2 nuclear density). CONCLUSIONS: Results indicate that a femtosecond laser can be used successfully in certain instances of traumatic cataract after penetrating eye injury, even if an anterior capsule laceration is present, and also after blunt trauma resulting in "white" cataracts.


Assuntos
Capsulorrexe/métodos , Catarata/etiologia , Ferimentos Oculares Penetrantes/cirurgia , Lasers de Excimer/uso terapêutico , Cristalino/lesões , Ferimentos não Penetrantes/cirurgia , Adulto , Ferimentos Oculares Penetrantes/etiologia , Feminino , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Ferimentos não Penetrantes/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA